ZeroStat CoatSpecifications
Introduction: Over 40 multiple electrical resistivity readings were taken by Mr. S.R. Clark on a standard Plexiglas sheet, measuring 3' X 3' (.250 thick). Plexiglas was chosen for it's highly insulative quality. Test One and Two represent standard EOS-ESD 7.1 RTG and PTP readings prior to coating with ZeroStat Stat Coat ESD Floor Finish. Test Three and Four represent standard EOS-ESD 7.1 RTG and PTP readings after coating with ZeroStat ESD Floor Finish. Specimen
Treatment: Said
Plexiglas Sheet was
treated with three
thin coats of ZeroStat
Coat Floor Finish,
applied with a clean
standard mop. Coats
were allowed to Dry
approximately 30 minutes
between applications.
Entire assembly was
further allowed to
cure overnight prior
to testing @ 71.9 0 F
and 28.7% Relative
Humidity. It should
be noted that ZeroStat
Coat is a metal free,
aqueous co-polymer
for use on asphalt,
rubber, vinyl composition,
linoleum, sealed or
painted wood and cement. Due
to its composition
I do not believe ZeroStat
Coat to be humidity
dependant relative
to its ability
to conduct an electrostatic
charge. Data from testing procedures were subsequently stored in non-volatile memory for transferal to Notebook Computer. Accuracy of readings at this range (with selected cables and electrodes utilized for this test) are +/- 2%. Original Calibration of Testing System was performed by said manufacturer on 8/25/99 and in accordance with NCSL Z540, traceable through reference standards maintained by the National Institute of Standards and Technology (NIST), by comparison to natural physical constants or self-calibrating ratio type measurements. |